Flat Roof Leak Detection & Measurement Technology
Flat Roof Leak Detection –
precise location, cost-effective restoration
Leaky flat roofs cause massive consequential damage. For over 30 years, DÖLCO has offered specialized leak detection equipment – from smoke gas generators to electro-acoustic and tracer gas systems, to dry detection via spark testing. The devices locate leaks without the need for complex dismantling of the roof waterproofing.
Causes
Causes of leaking flat roof membranes
- ▸Damage to the waterproofing membrane due to structural or environmental influences
- ▸Inadequate drainage systems
- ▸Faulty planning and execution
- ▸Incorrect positioning of insulation and vapor barrier
- ▸Condensation moisture due to lack of ventilation
- ▸Deformation and cracks due to thermal stress
- ▸Unsuitable materials during initial waterproofing
Consequences
Consequences of flat roof leaks
- ▸Water penetrates the insulation layer, leading to permanent dampness
- ▸Thermal insulation properties of the insulation layer are lost
- ▸Rising heating and cooling costs due to poor thermal insulation performance
- ▸Increased risk of mold on ceilings and walls
- ▸Summer vapor pressure can cause further damage to the waterproofing
Methods
How the detection methods work
Depending on the roof structure, accessibility, and extent of damage, a different method is used – always with the goal of finding the leak precisely and quickly. The diagrams show step-by-step how it works.
Smoke gas method
The DÖLCO RG5 fog generator blows fog under the roof waterproofing. Where the waterproofing is leaking, it emerges visibly – the leak can be marked directly.
- 1Set up RG5 – Fill with fog fluid, connect hose.
- 2Install nozzle – Insert bitumen or foil nozzle into the waterproofing.
- 3Inject fog – Fine-tune pressure with Drive-Control – the fog spreads under the waterproofing.
- 4Mark exit point – The smoke emerges visibly at the leak.
Electro-acoustics
The DÖLCO FD3 generator applies an AC voltage to the building's grounding. The signal travels via walls and ceilings into the damp insulation and emerges through the leak to the surface. Follow it with the measuring probe – the tone in the headphones increases towards the leak.
- 1Generator – applies an AC voltage to the building's grounding.
- 2Walls and concrete ceiling – conduct the signal upwards.
- 3Capacitive coupling – via the surfaces of the ceiling and vapor barrier into the damp insulation.
- 4Through the leak – to the damp surface.
- 5Measuring probe – as a counter-electrode: The current flows across the surface to the leak, the receiver indicates the direction.
Tracer gas method
Forming gas is introduced under the waterproofing. The hydrogen contained within spreads in the insulation layer and rises at the leak – where the TG1 detects it.
- 1Forming gas – 95% nitrogen / 5% hydrogen – non-flammable.
- 2Injection – via the tracer gas unit of the RG5 and a nozzle under the waterproofing.
- 3Distribution – The hydrogen spreads and rises at the leak.
- 4Surface search – Scan with the FD5 sensor carriage and the TG1 – active suction from the measuring hood.
- 5Pinpoint location – with the handheld probe of the TG1.
DC spark testing (dry detection)
Dry detection without flooding: The DÖLCO DCF35 works with high voltage. Where the waterproofing has a hole, crack, or pore, a spark jumps to the moisture underneath. Damp insulation or high humidity in the insulation layer is sufficient for this.
- 1Grounding – Connect grounding cable to the building's grounding.
- 2Select test voltage – 1–35 kV continuously adjustable, matching the waterproofing thickness.
- 3Scanning – Move the fan brush over the dry waterproofing.
- 4Defect – At the hole, a spark jumps to the moisture under the waterproofing – visual and acoustic alarm, the pore counter tracks the count.
Product overview
Flat roof leak detection devices – all models
Contact
Flat roof leak found?
Our team of experts will advise you on the suitable detection devices and drying concepts for your flat roof project. Contact us now.